Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Width | 6.2 mm |
---|---|
Height | 93.1 mm |
Depth | 101.2 mm |
Ambient temperature (operation) | -20 °C ... 65 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Degree of protection | IP20 |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Frequency input | Frequency input |
---|---|
Configurable/programmable | Yes |
Frequency measuring range | 0.002 Hz ... 20 kHz (DIP switch) |
Available input sources | NPN/PNP transistor outputs |
NAMUR initiators | |
Floating relay contact (dry contact) | |
Max. input amplitude | 30 V (incl. DC voltage) |
Output name | Voltage output / current output |
---|---|
Number of outputs | 1 |
Configurable/programmable | Yes |
Voltage output signal | 0 V ... 5 V |
1 V ... 5 V | |
0 V ... 10 V | |
10 V ... 0 V | |
Current output signal | 0 mA ... 20 mA |
4 mA ... 20 mA | |
20 mA ... 0 mA | |
20 mA ... 4 mA | |
Max. output voltage | approx. 12.3 V |
Max. output current | 24.6 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/output load current output | 500 Ω (at 20 mA) |
Ripple | < 20 mVPP |
< 20 mVPP (at 500 Ω) | |
Step response (0–99%) | < 35 ms (At f > 500 Hz) |
Supply voltage range | 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
---|---|
Typical current consumption | < 28 mA (at IOUT = 20 mA, 24 V DC, load 500 Ω) |
Power consumption | < 800 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω) |
Connection method | Screw connection |
---|---|
Stripping length | 12 mm |
Screw thread | M3 |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 26 ... 12 |
No. of channels | 1 |
---|---|
Transmission error in the set measuring range | 0.1 % |
Maximum temperature coefficient | 0.01 %/K |
Status display | LED red |
Operating elements | Press/slide button |
Protective circuit | Transient protection |
Electrical isolation | Basic insulation according to EN 61010 |
Overvoltage category | II |
Degree of pollution | 2 |
Rated insulation voltage | 50 V AC/DC |
Test voltage, input/output/supply | 1.5 kV (50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Color | green |
Housing material | PBT |
Mounting position | any |
Assembly instructions | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada | UL 508 Listed |
Class I, Div. 2, Groups A, B, C, D T4 | |
Class I, Zone 2, Group IIC | |
Certificate of classification | DNV GL 14085-15HH |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Designation | Electromagnetic RF field |
---|---|
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 0.1 % |
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 2 % |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 0.3 % |
Electromagnetic compatibility | Conformance with EMC directive |
---|---|
Noise emission | EN 61000-6-4 |
Standards/regulations | EN 61000-4-2 |
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
EN 61000-4-4 | |
EN 61000-4-5 | |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Electrical isolation | Basic insulation according to EN 61010 |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada | UL 508 Listed |
Class I, Div. 2, Groups A, B, C, D T4 | |
Class I, Zone 2, Group IIC |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 4.0 | 27210100 |
---|---|
eCl@ss 4.1 | 27210100 |
eCl@ss 5.0 | 27210100 |
eCl@ss 5.1 | 27210100 |
eCl@ss 6.0 | 27210100 |
eCl@ss 7.0 | 27210120 |
eCl@ss 8.0 | 27210120 |
eCl@ss 9.0 | 27210120 |
ETIM 4.0 | EC002653 |
---|---|
ETIM 5.0 | EC002653 |
ETIM 6.0 | EC002653 |
ETIM 7.0 | EC002653 |
UNSPSC 6.01 | 30211506 |
---|---|
UNSPSC 7.0901 | 39121008 |
UNSPSC 11 | 39121008 |
UNSPSC 12.01 | 39121008 |
UNSPSC 13.2 | 39121008 |
UNSPSC 18.0 | 39121008 |
UNSPSC 19.0 | 39121008 |
UNSPSC 20.0 | 39121008 |
UNSPSC 21.0 | 39121008 |